Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd

CN/EN

All
  • All
  • Product Management
  • News and Information
  • Enterprise Download

Temperature and Humidity Transmitter

Product Details Ordering Information Download Materials Related video Application Cases

Temperature and Humidity Transmitter

Equipped with interchangeable probe inputs or fixed/integrated probes, provide highly accurate analog or digital output measurements for a wide range of industrial applications—including process monitoring and control, cleanrooms, controlled environments, data centers, building management systems, storage areas, swimming pools, museums and art galleries, and many others.

| HF1 Series

 

The HygroFlex1 series is a new, cost-effective transmitter 

for measuring relative humidity and temperature in the 

HVAC field. The HF1 is equipped with the Hygromer® IN-1 sensor and offers exceptional value for money. By selecting the optional HW4 software, you can adjust the measurement range and calibrate and characterize the transmitter

Feature

√ 23℃ ±5℃ accuracy: ±2%RH / ±0.3℃; ±1.5%RH / ±0.2℃ (upgraded version) 
√ Measurement range: -20~60℃ / 0~100%RH 
√ Compact size, easy to install 
√ USB port 
√ Factory calibration: 35% RH, 80% RH

| HF3 Series

 

The HygroFlex3 series transmitters are suitable for applications requiring precise measurement of temperature and humidity. From the HVAC industry to greenhouses and museums, from storage rooms and libraries to subways and office environments, the HF3 series transmitters can meet all these needs.

Feature

√ 23℃ ±5℃ accuracy: ±2%RH / ±0.2℃ 
√ Measurement range: -40~60℃ / 0~100%RH 
√ Operating range: -40~60℃ / 0~100% RH, with display: -10~60℃ 
√ Analog output can be software-configured. 
√ Configuration interface 
√ Three-point calibration at 23℃, 10%, 35%, and 80% RH 
√ Dew point output

| HF5 Series

 

The HygroFlex5 series is compatible with all HC2 probes equipped with the AirChip chip. Thanks to the high precision of these probes, the HF5 series transmitters are capable of performing highly accurate measurements. This transmitter series features several innovative technologies that make parameter setting and calibration exceptionally convenient.

Feature

√ Up to two interchangeable HC2A probes 
√ Accuracy: ±8% RH and ±0.1℃ at 10–30℃ (commonly used accuracy) 
√ Measurement range: -50~100℃ / 0~100%RH (commonly used range) 
√ Operating range: -40~60℃ / 0~100% RH, with display: -10~60℃ 
√ Digital output can be used in combination with analog output. 
√ Can be used as a system verification simulator (requires operation via HW4 software and communication cable). 
√ Configuration interface

| CRP5 Series

 

The CRP5 cleanroom panel is equipped with a diaphragm sensor for differential pressure measurement, offering excellent performance. The CRP5 features both analog and digital communication capabilities, making it easy to integrate into any monitoring system. It meets GMP validation requirements, has been carefully designed, and is specifically optimized for laboratory and cleanroom applications.

Feature

√ Specifically designed for sterile rooms 
√ The detachable temperature and humidity probe makes adjustment and cleaning easier. 
√ Compatible with FDA 21 CFR Part 11 and GAMP 
√ Accuracy: Pressure ±1.0%FS; Temperature ±0.2℃; Humidity ±1.5%RH 
√ Digital communication via Ethernet RJ45 or TCP/RTU network communication protocols 
√ Analog and digital signal input 
√ The front panel features a differential pressure measurement and calibration interface. 
√ Relay or color TFT alarm 
√ Highly corrosion-resistant glass front panel

| HygroFlex5-EX

 

The HygroFlex5-EX series consists of a dual-channel transmitter, a product specifically developed for precise measurement of temperature and humidity in explosive environments, and complies with international standards. The ROTRONIC HF5-EX series transmitters feature a robust aluminum housing and come equipped with a display. Paired with a durable stainless steel probe, they can be used in Zone 0/Zone 20.

Feature

√ Measure relative humidity and temperature 
√ Accuracy: ±8% RH and ±0.1℃ at 10~30℃ 
√ Can output dew point and other psychrometric calculation parameters 
√ Can operate safely in hazardous explosive areas 
√ Intrinsically Safe Circuit Design 
√ No intrinsically safe power supply required 
√ Interchangeable stainless steel probe 
√ Two temperature certifications (T4/T5)

 

| HF1 / HF3


 

HF1

HF3

Type

Fixed probe

 

Application

HVAC

 

Scope of work

-20-50 Celsius / 0-100 %RH

-40 to -60 Celsius / 0-100 %RH

Accuracy @ 23 Celsius

±2% RH (10-90% RH) / ±0.3 K

<±2 %RH / ±0.3 K

Long-term stability

<1.5% rH/ Year

<1% RH/ Year

Sensor

Humidity: Rotronic IN1 / Thermistor

Humidity: Rotronic IN1 / PT100 A Level

Show

Optional with or without

Power supply

12-28 VAC / 15-40 VDC

HF32 2 Line: 10-28 VDC

HF33 3/4 Line: 18–40 VDC / 13–28 VAC

Output parameter

Humidity and temperature

Humidity and temperature

Output

2 An analog output 2 Line or 3/4 Line, freely expandable

Output signal

2 Line: 4-20 mA

3/4 Line: 0(4)-20 mA

0–1/5/10 VDC

Housing type

Wall mounting and pipe installation

Wall-mounted, pipe and wall installation

Housing material

ABS

 

Size

Wall-mounted 105x172 mm

Wall-mounted 101x182 mm

| CRP5 Series


 

CRP5

Accuracy @ 23 ±5 Celsius

±1.0% Full scale (Pa)

Parameter

Differential pressure, temperature, humidity, digital and analog outputs

Probe

HC2-CRP ; Replaceable: Any HygroClip2 Probe

Scope of application

-5...60 Celsius (23...140°F) / 0...100% RH

Measurement principle

Diaphragm sensor

Measurement range

±50 Pa / ±100 Pa / ±250 Pa / ±500 Pa & -100...200 Celsius ( Depends on the probe. ) / 0...100 %RH

Withstand voltage

0.7 bar (70,000 Pa)

Pressure connection

Front: Hose connector Ø 6 mm x 10 mm

Next: Hose connector Ø 4 mm x 10 mm

Medium

Air and non-corrosive gases

Precision analog output

±5 mV ( Voltage output )

±20 mu A ( Current output )

Digital output

6 Solid-state relay for roads

Switched-capacitor

<50 VDC @ <2A , when considering polarity

<35 VAC @ <1A , without considering polarity

Zero drift

Compensation ( Manual or automatic zero adjustment )

Power consumption

20...48 VDC / 18...35 VAC

<500 mA

Display type

Colorful TFT Show

Electrical connection

On the back screw terminal

Measurement interval

1 s

Menu Navigation

4 An optical key

Software update

Through HW4 Software

Analog output

4 The path can be freely configured.

Analog output signal ( Standard )

0 / 4...20 mA or 0...1 / 5 / 10 V

Communication interface

Ethernet (Modbus TCP, HW4) / RS-485 (Modbus RTU, HW4)

Permissible load

>10 kΩ ( Voltage output )

<500 Ω ( Current output )

Fire rating

Compliant UL94-HB

Shell

Front panel: Glass

Back panel: Steel plate

IP Protection level

Front: IP65 ( Sensor removed )

Behind: IP20

Install

Wall-mounted

Service interface

UART

FDA / GAMP

FDA 21 CFR Part 11 / GAMP5

CE / EMC Consistency

EMC Instruction 2004/108/EC

Storage and Transportation Conditions

-5...60 Celsius (23...140°F) / 0...100% RH

Size

180 x 300 x 72 mm

Weight

1,700 g ( With humidity sensor )

1,550 g ( Does not include a humidity sensor )

| HF5 / HF5-EX


 

HF5

HF5- EX

Order number

 

HF520 EX

Type

1x Interchangeable HC2A Probe

Application

Pharmaceutical industry

Oil, natural gas, steel mills

Scope of work

-40 to -60 Celsius / 0-100 %RH -10-60 °C display

Measurement range

-100-200 Celsius / 0-100 %RH , depending on the specific probe

Compatible probe

HC2A-S Series, HC2A-IC/IM/IEHC2-CPHC2-HK

HC2-SM-EX / HC2-IM-EX / HC2-IE-EX / HC2-LDP-EX

Probe cable length

5m Passive; accessible 100m Active cable

2/5/10 m

Accuracy @ 23°C

±0.8 %RH / ±0.1 K ( Normal value ) , depending on the specific probe

Long-term stability

<1 %RH ( Normal value ) , depending on the specific probe

Sensor

Depends on the specific probe.

Show

Optional with or without

Power supply

HF52 2 Line: 10-28 VDC

HF53 3/4 Line: 15–40 VDC / 12–28 VAC

HF54 Current isolation 9…36 VDC

HF56 Current isolation 100-240 VAC

10…28 VDC

Output parameter

Humidity and temperature

Calculation parameters

All humidity value calculations

Output

2 An analog output 2 Line or 3/4 Line, optionally with freely expandable digital output (LAN. RS-485)

2 One analog output, 2 Line

Output signal

2 Line: 4-20 mA 3/4 Line: 0(4)-20mA 0–1/5/10 VDC

2 Line 4…20 mA

Housing type

Wall-mounted and duct-mounted installation

Housing material

ABS

Aluminum

Size

Wall-mounted 160x206 mm (with 🛡️) HC2A-S )

Wall-mounted 160x210 mm (Contains HC2-SM-EX )