Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd
Product Category
Karl Fischer Micro Moisture Analyzer CA-310
New generation Karl Fischer Moisture Titrator CA-310

1. Scheduled time—automatically powers on, and the instrument stabilizes automatically, eliminating the need for a long wait before starting the test.
2. High-speed electrolysis mode: The instrument features a stable and faster detection speed, enhancing detection efficiency while also indirectly reducing the consumption of Karl Fischer reagents and other consumables.
3. Standard Operating Procedure (S.O.P.) Record: A standard procedure for testing a specific sample can be entered into the instrument. Subsequently, the instrument will automatically prompt the operator to perform the sample test according to the standard operating method.
4. 8.4-inch color touch screen with an intuitive and clear operating interface, featuring a Chinese-language user interface. Colorful window display: Utilizes a large-color screen for enhanced visual clarity.
5. Higher detection accuracy: In an ideal environment, it can detect trace amounts of moisture with good repeatability.
6. The console can connect to up to 4 detection channels. Multiple channels provide better reference for experimental results and also enhance detection efficiency.
7. The console can wirelessly control the detection channel (optional).
8. Stepwise temperature control: The vaporization device automatically determines the optimal heating temperature by detecting the evaporation rate of the sample’s moisture.
9. Electrodes with or without a diaphragm can be selected:
Membrane-free electrode: Can use a single-component AQUAMICRON conductive solution, making daily liquid replacement and maintenance even more convenient.
Membrane electrodes: They can analyze a wide variety of samples and are capable of detecting special substances such as ketones, low-molecular-weight acids, and certain alcohols.
10. Data integrity: Supports GLP/GMP.
11. USB input/output interface: Allows saving measurement results, as well as various internally and externally connected interfaces for different settings.
How to choose the right moisture meter?

Multiple moisture vaporization devices and an automatic sample injection system
| VA-300 Solid Sample Moisture Vaporization Device (Sample Boat Type)
A moisture vaporization device suitable for most solid or quasi-solid samples, such as plastic pellets, carbon powder, inorganic salts, battery separators, liquid crystals, coatings, food, pharmaceuticals, and more.
| Heating temperature |
70~300 Celsius |
| Heating module |
Transparent conductive glass |
| Injection volume |
10g The following |
| Detection range |
≥ 5ppm |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100 ~120V (50/60 Hz) 160VA AC 220 ~ 240V (50/60 Hz) 740VA |
| Size |
About 325 (W) x 170 (D) x 260 (H) mm |
| Quality |
About 4kg |
| VA-210 Viscous Liquid Sample Moisture Vaporization Device
Suitable for viscous liquid samples such as heavy oil, lubricating oil, and tar products.
| Heating temperature |
70~199 Celsius |
| Heating module |
Transparent conductive glass |
| Injection volume |
50g The following |
| Detection range |
≥ 5ppm |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100 ~120V (50/60 Hz) 160VA AC 220 ~ 240V (50/60 Hz) 740VA |
| Size |
About 120 (W) x 220 (D) x 230 (H) mm |
| Quality |
About 3kg |
| VG-200 Gas and Liquid Gas Quantitative Sampling Device
Sample injection for gases and liquefied gases. The gas or liquefied gas to be measured can be quantified—either by mass or by volume—and then injected into the titration cell.
| Heating temperature |
Room temperature ~90 Celsius |
| Injection speed |
100–600 ml/min |
| Injection volume |
0.1~99 g |
| Detection range |
≥ 5ppm |
| Withstand voltage |
1MPa |
| Power supply |
AC 100~120V (50/60 Hz) 44VA AC 220~240V (50/60 Hz) 48VA |
| Size |
About 150 (W) x 350 (D) x 270 (H) mm |
| Quality |
About 6kg |
| VA-230 Solid Sample Moisture Vaporization Device (Syringe Bottle Type)
This moisture vaporization device, which uses disposable sample vials for heating and vaporization, is suitable for most solid or quasi-solid samples, such as plastic pellets, carbon powder, inorganic salts, battery separators, liquid crystals, coatings, food, pharmaceuticals, and more.
| Heating temperature |
70~300 Celsius |
| Heating module |
Aluminum block heater |
| Injection volume |
Less than the quality 10g or volume less than 2.5ml |
| Detection range |
≥ 30ppm |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100~120V (50/60 Hz) 140VA AC 220~240V (50/60 Hz) 280VA |
| Size |
About 300 (W) x 135 (D) x 220 (H) mm |
| Quality |
About 3.5kg |
| VA-121 Attachment Water High-Temperature Moisture Vaporization Device (Sample Boat Type)
It can be heated up to a maximum of 1000℃ and is suitable for determining the content of surface water and adsorbed water in ores, rare earths, inorganic salts, and metal oxides.
| Heating temperature |
250~1000 Celsius |
| Heating module |
Electric stove (iron-chromium-aluminum resistance wire) 800W |
| Injection volume |
10g The following |
| Detection range |
≥ 5ppm |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100~120V (50/60 Hz) 1100VA AC 220~240V (50/60 Hz) 1100VA |
| Size |
About 420(W) x 260(D) x 420(H) mm |
| Quality |
About 15.5kg |
| VA-122 Dual-Furnace High- and Low-Temperature Model, with High-Temperature Moisture Vaporization Device for Adsorbed Water (Sample-Loading Boat Type)
They are divided into high-temperature furnaces and low-temperature furnaces. The low-temperature furnace heats to a temperature range of 70–300℃, while the high-temperature furnace heats to a temperature range of 250–1,000℃. These furnaces can specifically determine the content of surface water and adsorbed water in ores, rare earths, inorganic salts, and metal oxides.
| Heating temperature |
70~300 °C, 250~1000 Celsius |
| Heating module |
Electric stove (iron-chromium-aluminum resistance wire) 1000W |
| Injection volume |
10g The following |
| Detection range |
≥ 10ppm |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100~120V (50/60 Hz) 1900VA AC 220~240V (50/60 Hz) 1900VA |
| Size |
About 690(W) x 290(D) x 410(H) mm |
| Quality |
About 20kg |
| VA-236S Automatic Sample Gasification Injection System (Syringe Bottle Type)
It can continuously and automatically analyze up to 33 samples (in vial format). It is suitable for plastics, rubber, food, pharmaceuticals, inorganic salts, powders, and other solid samples. A specially designed sampling needle allows the analysis of certain oil samples.
| Heating temperature |
70~300 Celsius |
| Heating module |
Aluminum block heater |
| Injection volume |
Less than the quality 10g or volume less than 2.5ml |
| Sample bottle |
At most 33 A detection bit, 3 An empty experimental slot |
| Carrier gas |
Nitrogen, flow rate 0.1 ~ 0.5 L/min |
| Power supply |
AC 100~120V (50/60 Hz) 200VA AC 220~240V (50/60 Hz) 250VA |
| Size |
About 370(W) x 560(D) x 400(H) mm |
| Quality |
About 18kg |

|
CA-310 Capacity Method Technical Parameters |
CA-310 Coulometric Technical Parameters |
||
|
Measurement method |
Karlfischer volumetric titration Possible 4 Channel simultaneous detection ( Optional Configuration ) |
Measurement method |
Karl Fischer coulometric titration Possible 4 Channel simultaneous detection ( Optional Configuration ) |
|
Control method |
Voltage Difference Detection and Control |
Control method |
Continuous Current Pulse Time Control |
|
Detection method |
Continuous current polarization potential difference |
End-point detection method |
Continuous current polarization potential difference |
|
Electrolytic current |
430mA (High-speed mode) 516mA ) |
||
|
Background value selection |
Automatic correction, continuous display, and display of the selected background value during testing. . |
||
|
Moisture determination range |
0.1 mg - 999.999 mg H 2 O |
Moisture determination range |
5 mu g-999.9999 mg H 2 O (Trial moisture testing requires a well-controlled experimental environment to obtain accurate results.) |
|
Mixing method |
Magnetic stirrer |
Mixing method |
Magnetic stirrer |
|
Titration cell |
Open titration cell, capacity 150ml |
Titration cell |
Closed titration cell, capacity 150mL |
|
Display |
8.4 Inch color LCD Touch display |
Display |
8.4 Inch color LCD Touch display |
|
File storage |
Detection method: 99 seed Titration standardization method: 99 seed Appointment scheduling: 99 seed Test result: 9999 item |
File storage |
Detection method: 99 seed Appointment scheduling: 99 seed Test result: 9999 item |
|
Computing function |
Moisture content calculation, data statistics, recalculation, and reanalysis of titration curves |
Computing function |
Moisture content calculation, data statistics, recalculation, and reanalysis of titration curves |
|
Burette |
Syringe specifications are optional. Syringe capacity: 10mL (Optional) 25mL ) Drip rate: 1mL/1.5sec Titration solution withdrawal rate: 1mL/1.5sec Accuracy: ± 0.02mL ( 10mL Syringe) |
Titration rate |
Maximum 2.64 mg H 2 O/min (43.2 mu g H 2 O /sec) |
|
Sensitivity |
0.1 mu g H 2 O |
||
|
Detection accuracy |
<0.3% RSD (Moisture greater than 1mg ) |
||
|
Printer |
Optional thermal printer or impact printer. |
Printer |
Optional thermal printer or impact printer. |
|
External access I/O |
Electronic balance (optional): Automatic weight input USB Interface X4, LAN Interface X1 |
External access I/0 |
Electronic balance (optional): : Automatic weight input USB Interface X4, LAN Interface X1 |
|
Additional features |
Data integrity (compliance with) GLP/GMP ) Common Faults Help Menu, Detecting Electrode Activation |
Additional features |
Data integrity (compliance with) GLP/GMP ) Common Faults Help Menu, Detecting Electrode Activation |
|
Australian testing model |
Be equipped with |
Australian testing model |
Be equipped with |
|
Operating environment |
Temperature: 15-40 Celsius Humidity: 85% The following ( No condensation ) |
Operating environment |
Temperature: 15-40 Celsius Humidity: 85% The following ( No condensation ) |
|
Power supply |
AC 100/115/230/240 V (50/60 Hz) 80 VA |
Power supply |
AC 100/115/230/240 V (50/60 Hz) 80 VA |
|
Size |
CA-310MC Approximately 245(W) x 160(D) x 215(H) mm CA-310STR Approximately 120 (W) x 340 (D) x 135 (H) mm CA-310BRT Approximately 110(W) x 320(D) x 275(H) mm |
Size |
CA-310MC Approximately 245(W) x 160(D) x 215(H) mm CA-310STR Approximately 120 (W) x 340 (D) x 135 (H) mm |
|
Weight |
CA-310MC Approximately 2.0kg CA-310STR Approximately 2.5kg CA-310BRT Approximately 3.5kg |
Weight |
CA-310MC Approximately 2.0kg CA-310STR Approximately 2.5kg |