Potentiometric Titrator GT-310

Product Details Ordering Information Download Materials Related video Application Cases

A brand-new high-precision potentiometric titration device 
Automatic Potentiometric Titrator GT-310

The all-in-one design of the brand-new titrator-moisture analyzer enables more comprehensive detection and analysis of sample quality. 
An 8.4-inch color touch-screen display that can simultaneously display and control up to 4 detection channels, offering excellent operability. 
The instrument is pre-equipped with multiple detection methods and features intelligent functions such as one-click detection and automatic instrument recognition, significantly improving detection efficiency. 
Modular design with high scalability allows connection to various external expansion devices such as solvent addition units, autosamplers, electronic balances, printers, and more.


4-channel simultaneous detection/simultaneous display function 
The GT-310 can accommodate up to 4 detection channels (with flexible combinations of titrator and Karl Fischer moisture analyzer channels). Multi-channel detection provides more data references for experimental results and significantly enhances the instrument's operational efficiency.


Intelligent Dosing Control 
The GT-310 features an improved human-machine interaction interface, making parameter settings more flexible and intuitive. 
● Controllable detection accuracy: You can intuitively set the drop volume and potential stability parameters, and choose among modes such as “Fine,” “Rough,” “Fast,” and “Slow.” 
● Smart endpoint detection: Enhances the ability to identify potential changes in the sample solution being tested, enabling precise control of the titrant volume even when the potential curve undergoes rapid fluctuations, thus preventing over-titration.


Titrant Curve Reanalysis Function 
Determine the optimal titration endpoint through the re-analysis function of the titration curve.


Method for detecting the endpoint of titration 
For titration processes with multiple inflection points, parameters can be set separately according to the state of potential changes, enabling each inflection point to be detected using the most appropriate method.


LIMS connectivity feature 
The test data results and audit trail records can be automatically transferred via Ethernet cable to a network-shared folder on the PC, with file formats in Text or PDF.


Automatic pH Correction 
When calibrating with a buffer solution, stability assessment is performed automatically. The same stability criteria can be used at any time to calibrate the pH electrode. (Regular manual stability assessments can also be conducted.)


Automated operation 
The standard analysis workflow (pH calibration + blank test + sample analysis) can be registered in the progress planning function, making daily use even easier. In addition, the GT-310 is equipped with a dedicated autosampler (GT-310MST) that can automatically perform a series of analytical procedures.


QR code scanner (optional) 
It can be connected to a QR code scanner to quickly scan and enter information such as sample names.


Wireless Control Adapter (optional) 
By optionally equipping a wireless adapter, the main controller can wirelessly remotely control the detection channel (titration device + stirring platform). When analyzing samples that are sensitive to environmental influences or pose volatile hazards, the detection channel can be placed inside a fume hood or glove box for isolated operation.


Foot switch and gesture controller (optional) 
You can optionally equip the device with a foot switch or a gesture-sensing controller to start the detection process. It’s particularly convenient if you need to place the GT-310 inside a fume hood or glove box for use.


Test titration 
The GT-310’s test titration function can automatically generate appropriate parameters when analyzing samples of unknown properties. This makes it easier for researchers to get started, allowing even beginners to smoothly carry out experiments under the guidance of the test titration function.


Operating system compliant with GLP/GMP standards 
● User management function 
● Data security features 
● SOP creation support feature 
● Electronic signature authentication 
● The operating system can independently implement data integrity (DI). 
● Audit trail feature (available for a fee)

| GT Titration Liquid Addition Unit GT-310BRT

 

High-precision droplet volume control, with a minimum droplet volume of 1 µL.

Higher-precision control of titration liquid addition enables more accurate titration analysis. In addition, the GT-310BRT can be used as a standalone device for manual titration or for setting and delivering fixed volumes of liquid.

| Burette

 

The GT-310 features a dead-volume-free burette that enables efficient displacement of titration reagents. Its one-touch slide-lock design makes burette installation and removal exceptionally simple, facilitating daily maintenance. (Compatible with the burettes used in the previous-generation automatic potentiometric titrator, the GT-200.)

20 ml burette (standard configuration)

Minimum Droplet Volume

1 mu L

Liquid addition error

( 20ml )

10 mu L ( 0.05% , better than ISO/EN/DIN8655-3 Standard requirements 0.2% )

Size

About 69(W) x 121(D) x 131(H) mm

Optional accessories

1mL Burette

5mL Burette

10mL Burette

With a temperature sensor 20mL Burette

| GT Mixing Table GT-310STR

 

Smart magnetic stirring platform with flexible on/off control 
The magnetic stirring switch on the GT stirring station can be adjusted via the main controller’s switch. This not only eliminates the need to manually turn the stirring switch on and off each time before or after starting/ending a measurement, but also prevents the magnetically stirred bar from spinning unexpectedly when placing the beaker, thus avoiding damage to the electrode. Moreover, the stirring speed can be set according to the parameters specific to different samples being analyzed, so there is no need to manually adjust the stirring speed every time.


Sealed titration beaker (optional) 
An optional dedicated sealed titration beaker is available for samples that require titration and analysis in a closed container.

| Fully Automatic Sample Injection System GT-310MST

 

The combination of the fully automatic sample injection device GT-310MST and the titration liquid addition unit GT-310BRT enables a variety of titration methods and allows for the automatic, continuous analysis of multiple samples. Two models are available, with 12- and 24-sample positions.

Cleaning pump 1: It contains pure water, used to clean water-soluble stains from the electrode and activate the electrode.

Cleaning pump 2: It is equipped with a cleaning solvent (pure water or organic solvent) for thoroughly removing stains from the electrode.

Cleaning pump 3 (Waste Liquid Pump): After a sample has been tested, the pump automatically extracts the waste liquid from the beaker and discharges it into a dedicated waste liquid container.

Performance

 

Description

 

Number of digits to be checked

12 Position or 24 position

Sample vial size

Conventional beaker: 100mL200mL

High beaker: 100mL200mL300mL

Erlenmeyer flask: 100mL

Disposable container or sealed beaker

Sample turntable operation mode

Automatic sample-loading turntable, capable of continuous detection for up to: 99 One sample

Electrode Cleaning Method

Standard configuration includes pump-jet cleaning for both pure water and organic solvents.

Sample pretreatment

Magnetic stirring pre-mixing, with accessories GT-310SD Automatically prepares solutions.

Power Supply and Power Consumption

AC 85V~260V 50/60Hz About 210VA

Dimensions and weight

12 Position: Approximately 440 (W) x 520 (D) x 425 (H) mm , about 18.9kg

24 Position: Approximately 475 (W) x 590 (D) x 425 (H) mm , about 19.5kg

| Solvent Addition Unit GT-310SD

 

The solvent addition unit GT-310SD can automatically add a specified amount of solvent into the sample beaker to dissolve the sample.

Performance

Description

Drive section

Liquid addition method

Step motor-driven plunger syringe for liquid filling

Power supply

Powered by the mixing station, a fully automatic sample injection device, or an extended power module.

Dimensions and weight

About 130 (W) x 315 (D) x 350 (H) mm , about 4.5kg

Solvent addition tube section

Liquid addition tube capacity

50mL Glass-cavity syringe

Pipeline switching method

Check valve switching method

Accuracy

± 2mL ± Liquid addition amount x2%

Inner cavity material

Glass, polytetrafluoroethylene, polypropylene, polyethylene, stainless steel, and ceramic

Infusion tubing

Phi 6x Phi 4 Polyethylene pipe

| Polarization Titration Detection Module GT-310PS

 

Extended detection module for constant-current polarization titration, constant-voltage polarization titration, conductivity titration, and potential difference titration.

Performance

Description

Constant-current polarization titration

Polarization current: 0~25.00( mu A)

Constant-voltage polarization titration

Polarization voltage: 0~2000 (mV)

Electrical conductivity

5 Controllable adjustment of the barrier

Power supply

Powered by the mixing station, a fully automatic sample injection device, or an extended power module.

Dimensions and weight

About 150 (W) x 220 (D) x 45 (H) mm , about 0.7kg

| Photometric Titration Apparatus GT-LDⅡ

 

Photometric detection apparatus for indicator titration and complexometric titration.

Performance

Description

Detection method

Fiber-optic immersion probe

Light source

Tungsten lamp

Interference Filter Slide (Optional)

530620nm Customizable filters for other wavelengths

( Arbitrary Wavelength Replacement Method for Visual Range )

Power Supply and Power Consumption

AC 100V~240V 50/60Hz About 10VA

Dimensions and weight

About 90 (W) x 265 (D) x 150 (H) mm , about 2kg

| Polarization Titration Integrated Module GT-310HUB

 

When using two or more polarization titration detection modules, an integrated module must be added as a supplement.

| Extended Power Module GT-310PS

 

When using three or more GT-310BRT or GT-310SD units, an additional expansion power module must be installed.

 

Automatic Potentiometric Titrator GT-310

Titration type

Potentiometric titration ( Acid-base neutralization, redox reaction, complexation, precipitation )

Optional polarization titration, conductivity titration, and spectrophotometric titration.

Detection range

0~14 pH

+2000 mV to -2000 mV

Titration method

   Conventional titration

Turning Point Method (INF) Set the potential. (SET-P) Turning point / Set potential (INF/SP) · Pre-Node Detection (Front-int) Post-intersection detection (Back-int) V Intersection detection (V-Int)

   Oil neutralization value - Official law (OIL-A)

   Oil neutralization value - Idiom (OIL-J)

   Recovery time (R-TIME)

   Potentiostatic Titration (STAT)

   Potential adjustment (ADJUST)

   Test titration (TEST)

* Can also be detected pKa

Test titration

When testing samples of unknown nature, suitable detection parameters are automatically generated. ( Drip volume control, criteria for determining the titration endpoint, etc. ) For reference. * You can also customize and modify the generated parameters.

Conditional preset

The newly created titration method file allows you to predefine three stages: injection volume, preset potential, and preset differential value.

Titration method setup

Customizable to create

Titration Method Document 99 Common titrants 99 Individual, blank sample 99 Individual, Progress Plan 99 Individual, calculation formula 99 One.

Complexometric titration

Can be set 9 Types of Titration Method Documents

Stirring method

Magnetic stirrer

Display

8.4 Inch touch-enabled master control screen ( Supports Chinese, English, Japanese, and more. )

Display content

Testing conditions, testing results ( Chart ) Wait

Data can be saved

9999 one ( Includes detailed test results, titration curves, titration parameters, and more. )

Computing function

Sample result calculation, statistical computation, recalculation, parameter reanalysis, image reanalysis

Printing device

Optionally equipped with a thermal printer, dot matrix printer, or A4 Printer.

* For information on the printer brands and models that are compatible, please contact us.

Peripheral interface

USB Interface x4 LAN Interface x1

Test results, backups of various settings / Restore

Electronic balance: can automatically input the sample’s mass.

Additional features

Data integrity DI Support (GLP/GMP Accessibility features )

Audit trail ( Optional ) Troubleshooting

Runtime environment

Temperature: 15~40 Celsius

Relative humidity: 80% The following ( No condensation )

Power Supply and Function

AC 100V ~240V 50/60Hz About 80VA

Dimensions and weight

CA-310MC Approximately 245 (W) x 160 (D) x 215 (H) mm , about 2.0kg

GT-310STR Approximately 120 (W) x 340 (D) x 215 (H) mm , about 2.5kg

 

 

GT Titration Liquid Addition Unit GT-310BRT

Burette capacity

20 mL ( Default standard configuration )1mL5mL 10 mL ( Optional )

Titration burette liquid addition accuracy

± 10 mu L ( 0.05% , better than ISO/DIN8655-3 Standard requirements 0.2% )

Minimum Droplet Volume

1 mu L

Inner cavity material

Polytetrafluoroethylene, glass

Titration reagent bottle rack

500 mL ~ 1 L Specification reagent bottle

Infusion tubing

Polytetrafluoroethylene material

Liquid suction and addition rate

10~600 µL/ Seconds (the set value varies depending on the burette's capacity)

Power supply

Consisting of a mixing table, GT Titrator liquid addition unit or extended power module power supply

Dimensions and weight

About 130 (W) x 380 (D) x 260 (H) mm , about 3.5kg

 

Product Introduction: Karl Fischer Moisture Analyzer & Automatic Potentiometric Titrator

2.6MB

文件下载
< 1 >