Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd

CN/EN

All
  • All
  • Product Management
  • News and Information
  • Enterprise Download

Nova Blood Gas Analyzer

Product Details Ordering Information Download Materials Related video Application Cases

The brand-new Nova blood gas analyzer

The new technology makes operation simpler and provides more inspection items.

Stat Profile Prime Plus is a comprehensive full-blood critical care analyzer that integrates 34 calculated results—including blood gases, electrolytes, metabolites, and carboxyhemoglobin saturation—into a single, compact, user-friendly analyzer.

Prime Plus delivers rapid results—complete test data is available in as little as 90 seconds—and offers comprehensive data protection through bidirectional connectivity and a powerful data management system.

Nova MicroSensor Technology

All Prime Plus biosensors utilize the proven Nova technology and come in a compact, maintenance-free sensor card format.

Nova’s MicroSensor card integrates all 22 analyses, including pulse oximetry.

In biopharmaceutical process monitoring, these parameters play a crucial role:

- pH: The pH of cell culture media affects cell growth and metabolism; maintaining an appropriate pH range is essential.

Helps with cell growth and proliferation.

- PCO2: Partial pressure of carbon dioxide. During cell culture, monitoring PCO2 can help assess...

Carbonate balance under cell culture conditions.

- PO2: Partial pressure of oxygen. Cells require sufficient oxygen for metabolism and growth; monitoring PO2 ensures that cells are maintained in an appropriate oxygen environment.

- Na⁺, K⁺, Cl⁻, Ca²⁺, Mg²⁺: These ions are essential for cell growth and metabolism, and monitoring their concentrations helps maintain the stability of the intracellular and extracellular environments.

- Glu: glucose. Cells require glucose as an energy source, and monitoring glucose concentration ensures that cells have sufficient energy for growth and metabolism.

- Lac: Lactic acid. Lactic acid is a metabolic byproduct produced by cells, and changes in its concentration can reflect the cells’ metabolic status and the suitability of the culture conditions.

A new type of disposable, maintenance-free detection technology

Prime Plus employs a novel multi-wavelength optical system that can scan a continuous spectrum of light wavelengths, enabling comprehensive CO-O saturation measurements without the need to lyse the sample. The optical components that come into contact with the sample are housed in a disposable sensor cartridge.

  • No cleaning or defatting required at all.
  • There’s no need for lysis or its associated mechanical components, nor are lysis and deproteinization reagents required. This enhances reliability while reducing maintenance and costs.

Carbon-Oxygen Blood Oxygen Saturation Test Menu

O2Hb COHb MetHb HHb tHb HbF* tBil*

*HbF & tBil not available in all markets

High-throughput screening technology

The Prime Plus’s exceptional throughput effortlessly handles high sample volumes in busy process laboratories. The Prime Plus delivers complete sample testing for 90 assays in approximately 20 seconds. In contrast, competing analyzers may take up to 4 minutes—even when reporting fewer assay results.

Clot protection

Prime Plus’s unique Clot Block™ sample flow path protects the sensor card from blockage by blood clots.

Two-way data management system

Suitable for all Nova Connect device

The NovaNet bidirectional connection system ensures timely and accurate capture of test results from Nova analyzers, and enables user terminals to remotely initiate testing commands and transmit sample information, allowing laboratory personnel to access data anytime, anywhere. The system also includes comprehensive cybersecurity protection and encryption, and can integrate with the laboratory’s data management system.

Automation, true liquid QC

Compared to electronic equivalent QC, liquid QC offers uniqueness.

Reliable analyzer performance testing.

Automated QC complies with U.S. CLIA, German RiLiBAK, and other international QC requirements.

A kit provides QC reagents for up to 30 days.

Users can specify an interval to run automatically.

Prime Plus Quality Control:

Process it in exactly the same way as the sample.

From the sample probe to the waste liquid container, follow exactly the same sample pathway as the sample itself.

Conduct the tests within the low, normal, and high ranges of the sample.

Supplemental Quality Monitoring (SQM)

Prime Plus provides automated electronic quality monitoring as a supplement to liquid QC. The SQM continuously monitors the status and performance of all analytical components—including sensors, reagents, calibrators, sample integrity, software, and electronic components—ensuring real-time, inter-sample performance accuracy.

Stat Profile Prime Plus® Specifications

Compact size

Prime Plus size, including CO-O saturation and the NovaNet bidirectional connection system:

 

 

 

 

 

Critical Care Test Menu Methodology
pH Direct ISE
PCO 2 Severinghaus
PO 2 Amperometric
SO 2 % Optical, reflectance
Hematocrit Conductivity/Na correction
No Direct ISE
K Direct ISE
Cl Direct ISE
iCa Direct ISE
iMg Direct ISE
Glucose Enzyme/Amperometric
Lactate Enzyme/Amperometric
Urea (BUN) Enzyme/Amperometric
Create Enzyme/Amperometric
Calculated Tests
eGFR A - aDO 2 ePV and delta PV
HCO 3- a/A Normalized iCa
Total Cost of Ownership 2 PO 2/FIO2 Normalized iMg
BE - ECF Anion Gap Osmolality
BE - b SBC Hemoglobin
A Base Excess O 2 Saturation
ePV (Estimated Plasma Volume)
pH/PCO2/PO2 Corrected to Patient Temperature
Respiratory Index (If % FIO) 2 value entered)
Actual Bicarbonate
Standard Bicarbonate
Oxygen Index (OI)
CO-Oximetry Tests  
HHb, deoxyhemoglobin O 2 Hb, oxyhemoglobin
MetHb, methemoglobin COHb, carboxyhemoglobin
tHb, total hemoglobin SO 2 %, oxygen saturation
tBil, total bilirubin HbF, fetal hemoglobin

 

Compact size

Prime Plus size, including CO-O saturation and the NovaNet bidirectional connection system:

 

Other features:

Full-color, 10.1-inch touchscreen, multilingual support, QC statistics, in-vehicle data management, automatic sampler, integrated capillary adapter, optional barcode scanner, QC data storage, optional mobile cart with UPS.

Microsensor card:

60 µL sample volume

Power requirements:

< 90 watts

Acceptable samples:

Whole blood (heparinized), arterial, venous, mixed venous, culture medium

Communication protocol:

ASTM, HL7, or POCT01-A2 connection format

 

Other Features

Full-color, 10.1-inch touchscreen, multilingual, QC statistics, onboard data management, automatic sampler, integrated capillary adapter,