Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd
Product Category
Interchim puriFlash Process Scale-up
PuriFlash ® 535-XL Guarantee of production capacity
Reliability, with remarkable loading capacity. Reliable and safe— 535XL Capable of semi-continuous production, effectively purifying compounds up to hundreds of grams. This system is compatible with various sizes. DAC Chromatographic columns (axially compressed columns) and preparative liquid chromatography columns—meeting all your purification needs. |
|
|
|
|
|
|
|
|
Intersoft ® X Genius Smart software User-friendly interface, easy to operate, and intelligent method development. | Control module 15 Inch touchscreen Remote control USB x4 RJ45 | Fraction collector 2 a reagent rack 112 pipe 18 x 150 mm Leakage and Waste Disposal System | Chromatographic column Inner diameter can reach 80 mm | Injection system Supports solid and liquid sample injection | UV :200-400nm UV :200-800nm (Pack-UV extended) Multi-wavelength and full-spectrum scanning for spectral visualization and purity confirmation. Flow cell: 0.3 mm / 40 µL |
PuriFlash ® 5.015‐XL Kilogram-scale preparation
Reliability and stability, with significant load-bearing capacity. Reliability, stability, and safety are key advantages of semi-continuous preparation, using... puriFlash 5.015-XL No matter what the magnification factor is, you can achieve production continuity on the same device. |
|
|
|
|
|
|
|
|
Intersoft ® X Genius Smart software User-friendly interface, easy to operate, and intelligent method development. | Control module 15 Inch touchscreen Remote control USB x 8 RJ45 | Fraction collector 3 a reagent rack 42 pipe 29.5 x 200 mm Leakage and Waste Disposal System | Chromatographic column Inner diameter can reach 150 mm | Injection system Supports liquid sample injection and dry sample loading. Column balance Load & Go Technology Six-way valve +10 Valve-controlled solid-phase loading | UV :200-400nm UV :200-800nm (Pack- UV extended) Multi-wavelength and full-spectrum scanning for spectral visualization and purity confirmation. Flow cell: 0.3 mm / 80 µL |
| Ultraviolet - Visible Spectrophotometer Detector
Choose the UV that suits your needs. - Visible Spectrophotometer Detector
PuriFlash Ultraviolet included with the device - The visible spectrophotometer detector is fully integrated into the acquisition module, and is composed of... InterSoft X Software control. Since the application is very simple, you only need to enter the desired wavelength into the software and can simultaneously select... 4 a single wavelength, in a manner identical to scanning (the total number of wavelengths available for both models can be included in this model), “Genius” Will be responsible for the acquisition and recording of chromatograms.
Each laboratory has different needs. Since we are eager to meet these needs and always provide you with the right solution, we recommend using two types of UV detectors:
200 – 400 nm (Standard – For proteins PF-020B Except)
200 – 800 nm (Compatible with this option) PuriFlash ® of the UV Expansion pack)
Real-time scanning across the entire wavelength and ultraviolet spectrum
Ultraviolet - The visible spectrophotometer detector is equipped with... “DAD” Technology (diode-array detector). This provides approximately one hundred diodes for scanning the entire wavelength range for detection, enabling real-time acquisition of the UV spectra of eluting compounds.
If you wish, you can at any time—even during operation or reprocessing—return to the peaks in the chromatogram to display the spectrum at the selected time and obtain identification of the elements as well as the purity of the purified compound.
|
Configuration |
PuriFlash ® 535-XL |
PuriFlash ® 5.015-XL |
|
|
Pump |
Flow rate (ml/min) |
400 |
825 |
|
Maximum pressure (bar) |
35 |
15 |
|
|
Quadruple Gradient Pump |
√ |
√ |
|
|
Air venting |
√ |
X |
|
|
Washing discs |
X |
√ |
|
|
Pump Washing Discs (Pack) |
X |
X |
|
|
Detector |
UV: 200 – 400 nm |
√ |
√ |
|
UV: 200 – 800 nm |
Pack-UVextended |
Pack-UVextended |
|
|
Purity Confirmation |
√ |
√ |
|
|
iELSD (pack) |
X |
X |
|
|
Load sample |
4 Electrically operated valve |
X |
X |
|
6 Electrically operated valve w/loop |
X |
X |
|
|
6 Pass-through valve +10 Electrically operated valve w/loop |
X |
X |
|
|
Liquid, Dry-Load Load sample |
√ |
√ |
|
|
Chromatographic Column Selection Valve |
6 Electrically operated valve |
X |
X |
|
System Configuration |
Tubings – after pump (ID) |
1/8” x 1.6mm |
1/8” x 2.4mm |
|
Flow cell |
0.3mm/40 mu L |
0.3mm/80 mu L |
|
|
Chromatography column holder |
Integration |
Pack-ColHolder |
Pack-process |
|
Pre-column Column support |
√ |
Pack-process |
|
|
Fraction collection |
Regular |
2 A reagent rack 112 pipe 18x150mm |
3 A reagent rack 42 pipe 29.5 x 200 mm |
|
Control module |
15 Inch touchscreen |
√ |
√ |
|
USB |
4 |
8 |
|
|
RJ45 |
√ |
√ |
|
|
Software |
Intersoft X |
√ |
√ |
|
Safety |
Leak detection (pump, collection rack, iELSD , bracket) |
X |
√ (except for the bracket) |
|
Solvent tray with drainage system |
√ |
√ |
|
|
Collector with drainage system |
√ |
√ |
|
|
Solvent level monitoring |
√ |
√ |
|
|
RFID |
X |
√ |
|
|
Fume Enclosure |
√ |
√ |
|
|
Size |
E:D:H (cm) |
35.5 × 47 × 77 |
40×51×75 |