Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd

CN/EN

All
  • All
  • Product Management
  • News and Information
  • Enterprise Download

Capillary tubes and fittings

Product Details Ordering Information Download Materials Related video Application Cases
 As quasi-UPLC systems have become increasingly popular, if the wrong tubing specifications and connector models are selected when switching column particle sizes, the excessive dead volume before the column can lead to deteriorated peak shapes and reduced column efficiency. 
Moreover, traditional stainless steel fittings or front-mounted hand-tightening fittings cannot accommodate columns from all brands after installation, often leading to 2 types of problems: 
  1. Leakage during use caused by excessively long pipelines or mismatched sealing rings; 
      2. The excessively short extension of the tubing leads to increased dead volume and degraded peak shape. 

Our Advantages:

Based on market feedback regarding the first 2 generations of HanKing hand-tightening connectors, combined with the demand for products capable of withstanding pressures up to 1200 bar, we have further optimized and upgraded our product portfolio. 

Compared to the 400-bar JointC hand-tightening connector, which features a PEEK blade ring as its sealing core, this new 1200-bar JointD hand-tightening connector assembly incorporates a sealing gasket housed within a capillary tube, creating a bellows-like structure. After tightening, this design achieves dual sealing—both at the flat surface and along the sides—minimizing dead volume to the greatest extent possible and optimizing the repeated insertion and removal lifespan to over 150 cycles. Moreover, thanks to our long-standing commitment to a modular structural design, both the capillary tubing and the connector itself can be replaced independently, significantly reducing users’ operating costs. 

Sealing Principle

 

 

Capillary Fitting Assembly for 600 bar - 1200 bar UPLC/HPLC

 

Ordering Information

0.11mm Inner diameter

Part No.

0.18mm Inner diameter

Part No.

90mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11EE090

HK-18EE090

105mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE105

HK-18EE105

150mm long capillary tube with pre-assembled hand-tight fittings at both ends.

HK-11EE150

HK-18EE150

220mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE220

HK-18EE220

250mm long capillary tube with pre-assembled hand-tightened connectors at both ends.

HK-11EE250

HK-18EE250

280mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE280

HK-18EE280

300mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11EE300

HK-18EE300

350mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE350

HK-18EE350

450mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11EE450

HK-18EE450

550mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE550

HK-18EE550

600mm long capillary tube with pre-assembled hand-tight fittings at both ends.

HK-11EE600

HK-18EE600

700mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11EE700

HK-18EE700

 

Ordering Information

0.11mm Inner diameter

Part No.

0.18mm Inner diameter

Part No.

90mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11DD090

HK-18DD090

105mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD105

HK-18DD105

150mm long capillary tube with pre-assembled hand-tight fittings at both ends.

HK-11DD150

HK-18DD150

220mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD220

HK-18DD220

250mm long capillary tube with pre-assembled hand-tightened connectors at both ends.

HK-11DD250

HK-18DD250

280mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD280

HK-18DD280

300mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11DD300

HK-18DD300

350mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD350

HK-18DD350

450mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-11DD450

HK-18DD450

550mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD550

HK-18DD550

600mm long capillary tube with pre-assembled hand-tight fittings at both ends.

HK-11DD600

HK-18DD600

700mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-11DD700

HK-18DD700

 

Capillary Fitting Assembly for 400 bar HPLC

We generally recommend that users employ one of two common configurations: either both ends feature hand-tightened connectors, or one end is equipped with a hand-tightened connector while the other end has a standard metal connector. Different capillaries are available—typically, 0.17 mm capillaries are suitable for Agilent HPLC systems, whereas 0.18 mm capillaries are better suited for HPLC systems from other brands such as Waters, Thermo, and Shimadzu. To ensure proper compatibility with various connecting components, we recommend selecting an appropriate capillary length to avoid unnecessary extra pre-column volume.

 

Ordering Information

0.17mm Inner diameter

Part No.

0.18mm Inner diameter

Part No.

90mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-17CC090

HK-18CC090

105mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC105

HK-18CC105

150mm long capillary tube with pre-assembled hand-tight fittings at both ends.

HK-17CC150

HK-18CC150

220mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC220

HK-18CC220

250mm long capillary tube with pre-assembled hand-tightened connectors at both ends.

HK-17CC250

HK-18CC250

280mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC280

HK-18CC280

300mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-17CC300

HK-18CC300

350mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC350

HK-18CC350

450mm long capillary tube with pre-assembled, hand-tightened connectors at both ends.

HK-17CC450

HK-18CC450

500mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC500

HK-18CC500

550mm long capillary tube with pre-assembled hand-tightened connectors at both ends.

HK-17CC550

HK-18CC550

600mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC600

HK-18CC600

900mm Long capillary tube with pre-assembled, hand-tightened fittings at both ends.

HK-17CC900

HK-18CC900

 

Ordering Information

0.17mm Inner diameter

Part No.

0.18mm Inner diameter

Part No.

90mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC090

HK-18AC090

105mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC105

HK-18AC105

150mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC150

HK-18AC150

220mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC220

HK-18AC220

250mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC250

HK-18AC250

280mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC280

HK-18AC280

300mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC300

HK-18AC300

350mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC350

HK-18AC350

450mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC450

HK-18AC450

500mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC500

HK-18AC500

550mm long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC550

HK-18AC550

600mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC600

HK-18AC600

900mm Long capillary tube, with a hand-tightened connector at one end and a short metal connector at the other end.

HK-17AC900

HK-18AC900

 

1/32" capillary tube

 

Ordering Information

0.12mm Inner diameter

Part No.

0.17mm Inner diameter

Part No.

90mm long capillary tube, with a 1/32” metal connector pre-installed at end A, and a short metal connector at end B.

HK-12AM090

HK-17AM090

105mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM105

HK-17AM105

150mm long capillary tube, with a 1/32” metal fitting pre-installed at end A and a short metal fitting at end B.

HK-12AM150

HK-17AM150

220mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM220

HK-17AM220

250mm long capillary tube, with a 1/32” metal fitting pre-installed at end A and a short metal fitting at end B.

HK-12AM250

HK-17AM250

280mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM280

HK-17AM280

300mm long capillary tube, with a 1/32” metal fitting pre-installed at end A, and a short metal fitting at end B.

HK-12AM300

HK-17AM300

350mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM350

HK-17AM350

450mm long capillary tube, with a 1/32” metal fitting pre-installed at end A and a short metal fitting at end B.

HK-12AM450

HK-17AM450

500mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM500

HK-17AM500

550mm long capillary tube, with a 1/32” metal fitting pre-installed at end A, and a short metal fitting at end B.

HK-12AM550

HK-17AM550

600mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM600

HK-17AM600

700mm Long capillary tube, with a 1/32” metal connector pre-installed at end A and a short metal connector at end B.

HK-12AM700

HK-17AM700

 

Hand-tightened connector

 

Ordering Information

Part No.

Short metal connector replacement pack (10 per pack)

HK-JointA

Long metal connector replacement pack (10 per pack)

HK-JointAA

Hand-tightened connector replacement pack (1 per pack)

HK-JointC

Hand-tightened connector replacement pack (1 per pack)

HK-JointD

Hand-tightened connector replacement pack (1 per pack)

HK-JointE

 

HK Pipeline Fitting Product Introduction

1.6MB

文件下载

Comprehensive Catalog of Liquid Chromatography Accessories and Consumables

45.4MB

文件下载
< 1 >