LC Parts & Consumables Analytical Light Source GC Parts & Consumables Synthesis and Purification General Instruments and Equipment Biotech-relatedCapillary tube and connector Ghost Peak Sniper Check Valve and Valve Core Reagent Waste Liquid Sealing Cap Guard Column and Filter Two-Way Connector Chromatography Mobile Phase Filter General Laboratory Consumables DWK Reagent BottleDeuterium Lamp for Instrument Manufacturing Replacement Deuterium Lamp for Instruments Deuterium Lamp Power Supply Hollow Cathode Lamp Photoionization Lamp (PID Lamp) 5W Xenon Flash Lamp Module FiberLight® Fiber Optic LampFused Silica Capillary Chromatography Column Ultra-Inert Capillary Chromatography Column High-Temperature Capillary Chromatography Column Gas Chromatography ConsumablesAIS Purification & Organic MS System Automated Peptide Synthesizer Thin Film Evaporator Synthesis Workstation Stirrer
18
2025
-
06
Determination of Moisture Content in Nicosulfuron Technical Grade Substance
Reference standard: GB 29383-2012 Nicosulfuron technical grade substance
[ Scope 】
This standard specifies the requirements for pyrazosulfuron-ethyl technical grade, the test methods, as well as the labeling, packaging, storage, transportation, and acceptance criteria.
This standard applies to the technical grade of nicosulfuron, which consists of nicosulfuron itself and impurities generated during its production.
Note: For other names, structural formulas, and basic physicochemical parameters of nicosulfuron, see Appendix A.
【Requirement】
Appearance: A grayish-white to earthy-yellow solid in granular or powdered form, free from any visible foreign matter and added modifiers.
Technical indicators: The technical grade of nicosulfuron shall also meet the requirements specified in Table 1.

[Experimental Method]
Determination of moisture content: Perform the test according to the "Karl Fischer method" specified in GB/T 1600. The use of a micro moisture analyzer with comparable accuracy is permitted.
GB/T 1600-2001 — Method for Determination of Moisture Content in Pesticides
Appendix A (Informative Appendix)
Other names, structural formulas, and basic physicochemical parameters of nicosulfuron
The other names, structural formula, and basic physicochemical parameters of the active ingredient of this product, nicosulfuron, are as follows:
Generic name: Nicosulfuron
ISO common name: nicosulfuron
CAS Registry Number: 111991-09-4
Chemical name: 2-(4,6-Dimethoxypyrimidin-2-ylcarbamoylsulfamoyl)-N,N-dimethyl nicotinamide
Structural formula:

Empirical formula: C 15 H 18 N 6 O 6 S
Relative molecular mass: 410.4
Bioactivity: Herbicide
Melting point: 141°C~144°C
Vapor pressure: 1.6 × 10⁻¹¹ Pa (20°C)
Solubility (25°C, g/kg): Water: 3.59 (pH=5 buffer solution), 12.2 (pH=7 buffer solution), 39.2 (pH=9 buffer solution); Acetone: 18; Ethanol: 4.5; Chloroform, Dimethylformamide: 64; Acetonitrile: 23; Toluene: 0.37; n-Hexane: <0.02; Dichloromethane: 160
Stability: The aqueous solution has a DT50 of approximately 15 days at 25°C (pH 5) and is stable at pH 7 and pH 9.
[Recommended]
Karl Fischer Moisture Analyzer CA-310 Volumetric Method

Instrument features:
1. Higher detection accuracy: Under ideal conditions, it can detect trace amounts of moisture (absolute water content as low as 5 μg) with excellent repeatability.
2. The console can connect to up to 4 detection channels. Multiple channels provide better reference for experimental results and also enhance detection efficiency.
3. Standard Operating Procedure (S.O.P.) Recording: A standard operating procedure for testing a specific sample can be entered into the instrument. Subsequently, the instrument will automatically prompt the operator to perform the sample test according to the standard operating method.
Technical specifications:
| Technical Specifications of the CA-310 Volumetric Micro Moisture Analyzer |
|
| Measurement method |
Karls Fischer volumetric titration Simultaneous 4-channel measurement (optional) |
| Moisture determination range |
0.1 ~ 999.999 mg H2O |
| Display screen |
8.4-inch color LCD touch screen, supports Chinese operation |
| File storage |
Detailed experimental data storage: 9,999 entries Instrument timing start/stop setting options: 99 types |
| Printer |
Optional thermal printer or impact printer. |
| Moisture vaporization device |
Can be used with VA-300, VA-200, VA-210, VA-230, VA-236S, VA-121, and VA-122 gasification units all feature stepwise temperature control functionality. |
| Bromine detection mode Burette |
Volume: 10 ml (optional with 2 ml, 5 ml, or 20 ml burettes) Titration accuracy: 0.1% Reagent filling speed: 0.7 ml/1 sec |
| External Access I/O |
Electronic balance: Automatic weight input 4 USB ports, 1 LAN port Import or export experimental data, backup/restore settings |
Keywords:
Related News
Contact Us
Address: Building 2, 8th Floor, No. 248 Guanghua Road, Minhang District, Shanghai
Scan to follow us
Scan to follow us
Call us.
Copyright © 2026 Shanghai HanKing Instrument & Equipment Co.,Ltd
Terms of Use
Privacy Policy
Address: Building 2, 8th Floor, No. 248 Guanghua Road, Minhang District, Shanghai市
Scan to follow us
Scan to follow us
Call us.
Copyright © 2026 Shanghai HanKing Instrument & Equipment Co.,Ltd
Terms of Use
Privacy Policy
Technical Support: Zhongqi Cross-border
Hu (Min) Emergency Management Crisis Xu [2023]201905