Quick Purifie - HanKing 'Ghost Peak Terminator' Microcolumns


HanKing 'Ghost Peak Terminator' microcolumns can efficiently absorb impurities in the mobile phase, significantly reducing irregular peaks during gradient elution, helping you save method development time.

Buy microcolumn and Get Metal Pipeline components for free!

 


 

Feature

Effectively eliminates ghost peaks generated during the mixing of the mobile phase and pump, improving the accuracy and reproducibility of analysis results;

Available in various specifications, allowing flexible selection according to different usage conditions to meet diverse application needs;

Uses special adsorption materials, resistant to high pressure, strong in impurity removal, and has a long service life.


 


 

Key Points for Use and Installation

1. Prep before installation: The column comes stored in methanol, so you need to flush it with methanol at a flow rate of 1.0 mL/min for 20 minutes first (don’t connect it to the chromatograph or detector).  

2. Connection location: It must be installed between the mixer and the injector, not after the injector, to avoid sample adsorption.  

3. Notes on gradient elution:  

- It’s recommended to extend the post-run equilibration time a bit.  
- If you need faster equilibration, you can choose a smaller column size (like 4.0×30mm).
 


 

Notes

Ion pair reagents: Tolerates tetrabutylammonium hydroxide, sodium heptanesulfonate, etc., but may shorten lifespan or cause irreversible adsorption.  

Mass spectrometry coupling: Trace leachables may occur; it’s recommended to flush in advance and do a compatibility test.  

Cleaning and storage:  

- Salt-free systems: Rinse with 80% methanol in water for 20 minutes before storing;  
- Salt-containing systems: First rinse with 10% methanol in water, then with 80% methanol in water before storing.
 


 

Specification Selection Table

规格选型.png
 


 

Case study

Trifluoroacetic acid-acetonitrile


 

三氟乙酸-乙腈.png

Spectra comparison under the same conditions:

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram

三氟乙酸-乙腈图谱连接鬼峰.png

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram

Trifluoroacetic acid-methanol

三氟乙酸-甲醇.png

Spectra comparison under the same conditions:

三氟乙酸-甲醇未接鬼峰.png

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

三氟乙酸-甲醇接鬼峰.png

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram

Phosphate-acetonitrile

磷酸盐-乙腈.png

Spectra comparison under the same conditions:

磷酸盐-乙腈未接鬼峰.png

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

磷酸盐-乙腈接鬼峰.png

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram

磷酸盐-甲醇

磷酸盐-甲醇


 

磷酸盐-甲醇.png

Spectra comparison under the same conditions:

磷酸盐-甲醇未接鬼峰.png

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

磷酸盐-甲醇接鬼峰.png

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

 