LC Parts & Consumables Analytical Light Source GC Parts & Consumables Synthesis and Purification General Instruments and Equipment Biotech-relatedCapillary tube and connector Ghost Peak Sniper Check Valve and Valve Core Reagent Waste Liquid Sealing Cap Guard Column and Filter Two-Way Connector Chromatography Mobile Phase Filter General Laboratory Consumables DWK Reagent BottleDeuterium Lamp for Instrument Manufacturing Replacement Deuterium Lamp for Instruments Deuterium Lamp Power Supply Hollow Cathode Lamp Photoionization Lamp (PID Lamp) 5W Xenon Flash Lamp Module FiberLight® Fiber Optic LampFused Silica Capillary Chromatography Column Ultra-Inert Capillary Chromatography Column High-Temperature Capillary Chromatography Column Gas Chromatography ConsumablesAIS Purification & Organic MS System Automated Peptide Synthesizer Thin Film Evaporator Synthesis Workstation Stirrer
03
2026
-
07
Quick Purifie - HanKing 'Ghost Peak Terminator' Microcolumns
HanKing 'Ghost Peak Terminator' microcolumns can efficiently absorb impurities in the mobile phase, significantly reducing irregular peaks during gradient elution, helping you save method development time.

Buy microcolumn and Get Metal Pipeline components for free!
Feature
Effectively eliminates ghost peaks generated during the mixing of the mobile phase and pump, improving the accuracy and reproducibility of analysis results;
Available in various specifications, allowing flexible selection according to different usage conditions to meet diverse application needs;
Uses special adsorption materials, resistant to high pressure, strong in impurity removal, and has a long service life.
Key Points for Use and Installation
1. Prep before installation: The column comes stored in methanol, so you need to flush it with methanol at a flow rate of 1.0 mL/min for 20 minutes first (don’t connect it to the chromatograph or detector).
2. Connection location: It must be installed between the mixer and the injector, not after the injector, to avoid sample adsorption.
3. Notes on gradient elution:
- It’s recommended to extend the post-run equilibration time a bit.
- If you need faster equilibration, you can choose a smaller column size (like 4.0×30mm).
Notes
Ion pair reagents: Tolerates tetrabutylammonium hydroxide, sodium heptanesulfonate, etc., but may shorten lifespan or cause irreversible adsorption.
Mass spectrometry coupling: Trace leachables may occur; it’s recommended to flush in advance and do a compatibility test.
Cleaning and storage:
- Salt-free systems: Rinse with 80% methanol in water for 20 minutes before storing;
- Salt-containing systems: First rinse with 10% methanol in water, then with 80% methanol in water before storing.
Specification Selection Table

Case study
Trifluoroacetic acid-acetonitrile

Spectra comparison under the same conditions:

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram
Trifluoroacetic acid-methanol

Spectra comparison under the same conditions:

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram
Phosphate-acetonitrile

Spectra comparison under the same conditions:

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

Connecting HanKing Ghost Peak Terminator Little Zhu Experimental Diagram
磷酸盐-甲醇
磷酸盐-甲醇

Spectra comparison under the same conditions:

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum

Unconnected HanKing Ghost Peak Terminator Little Zhu Experimental Spectrum
Keywords:
Related News
Contact Us
Address: Building 2, 8th Floor, No. 248 Guanghua Road, Minhang District, Shanghai
Scan to follow us
Scan to follow us
Call us.
Copyright © 2026 Shanghai HanKing Instrument & Equipment Co.,Ltd
Terms of Use
Privacy Policy
Address: Building 2, 8th Floor, No. 248 Guanghua Road, Minhang District, Shanghai市
Scan to follow us
Scan to follow us
Call us.
Copyright © 2026 Shanghai HanKing Instrument & Equipment Co.,Ltd
Terms of Use
Privacy Policy
Technical Support: Zhongqi Cross-border
Hu (Min) Emergency Management Crisis Xu [2023]201905