Welcome to Shanghai HanKing Instrument & Equipment Co.,Ltd
05
2025
-
06
Determination of the Mass Fraction of Water in Acetamiprid Technical Grade Substance
Reference standard: GB 29384-2012 Acetamiprid technical grade
This standard specifies the requirements for acephate technical grade, test methods, as well as labeling, packaging, storage, transportation, and acceptance criteria.
This standard applies to acetamiprid technical grade, which consists of acetamiprid itself and impurities generated during its production.
Note: Acetamiprid and its impurities, acetamide and methamidophos. O , O , S - For other names, structural formulas, and basic physicochemical parameters of trimethyl thiophosphate, see Appendix A.
Appearance: White crystalline powder with no visible foreign impurities.
Technical indicators: The technical grade of acephate shall also meet the requirements specified in Table 1.

Determination of Moisture Mass Fraction
Perform according to the "Karl Fischer method" in GB/T 1600.
GB/T 1600-2001 — Method for Determination of Moisture Content in Pesticides
Appendix A (Informative Appendix)
Acetamiprid and its impurities, acetamide and methamidophos. O , O , S - Other names, structural formulas, and basic physicochemical parameters of trimethyl thiophosphate
The other names, structural formula, and basic physicochemical parameters of the active ingredient acephate in this product are as follows:
ISO common name: acephate
CAS Registry Number: 30560-19-1
Chemical name: O , S -Dimethyl- N - Acetyl thiophosphoramidate
Structural formula:

Empirical formula: C 4 H 10 NO 3 P.S.
Relative molecular mass: 183.2
Bioactivity: Insecticide
Melting point: 88°C~90°C
Vapor pressure (24°C): 0.226mPa
Relative density (20°C): 1.35
Solubility (20°C, g/L): 790 in water; 151 in acetone; >100 in ethanol; 35 in ethyl acetate; 16 in benzene; 0.1 in n-hexane
Stability: Stable under slightly acidic conditions, half-life DT 50 (40°C) 60 h (pH = 9), 710 h (pH = 3).
The other names, structural formulas, and basic physicochemical parameters of the impurity acetamide in this product are as follows:
ISO common name: acetamide
CAS Registry Number: 60-35-5
Chemical name: Acetamide
Structural formula:

Empirical formula: C 2 H 5 NO
Relative molecular weight: 59.07
Melting point: 81°C
Boiling point: 222°C
Vapor pressure (65°C): 0.13kPa
Relative density (20°C): 1.16
Solubility: Soluble in water, ethanol, chloroform, pyridine, and glycerol; slightly soluble in diethyl ether; insoluble in n-octanol.
The other names, structural formula, and basic physicochemical parameters of the impurity methamidophos in this product are as follows:
ISO common name: methamidophos
CAS Registry Number: 10265-92-6
CIPAC digital code: 355
Chemical name: O , S -Dimethylamino thiophosphate
Structural formula:

Empirical formula: C 2 H 8 NO 2 P.S.
Relative molecular mass: 141.1
Bioactivity: Insecticidal, acaricidal
Melting point: 44.9°C
Vapor pressure: 2.3 mPa (20°C), 4.7 mPa (25°C)
Relative density (20°C): 1.27
Solubility (20°C, g/L): In water >200, in isopropanol >200, in dichloromethane >200, in n-hexane 0.1–1, in toluene 2–5.
Stability: It is stable at room temperature but decomposes upon heating, so it has no boiling point. It is stable in the pH range of 3 to 8, with a half-life of DT. 50 1.8 years (pH 4), 120 hours (pH 7), 70 hours (pH 9).
Impurities in this product O , O , S - The other names, structural formulas, and basic physicochemical parameters of trimethyl thiophosphate are as follows:
Generic name: O , O , S -Trimethyl thiophosphate
CAS Registry Number: 15230-5
Chemical name: O , O , S -Trimethyl thiophosphate
Structural formula:

Empirical formula: C 3 H 9 O 3 P.S.
Relative molecular mass: 156.15
[Recommended]
Karl Fischer Moisture Analyzer CA-310 Volumetric Method

1. Higher detection accuracy: Under ideal conditions, it can detect trace amounts of moisture (absolute water content as low as 5 μg) with excellent repeatability.
2. The console can connect to up to 4 detection channels. Multiple channels provide better reference for experimental results and also enhance detection efficiency.
3. Standard Operating Procedure (S.O.P.) Recording: A standard operating procedure for testing a specific sample can be entered into the instrument. Subsequently, the instrument will automatically prompt the operator to perform the sample test according to the standard procedure.
| Technical Specifications of the CA-310 Volumetric Micro Moisture Analyzer | |
| Measurement method | Carl Fischer volumetric titration—4-channel simultaneous determination (optional) |
| Moisture determination range | 0.1 ~ 999.999 mg H 2 O |
| Display screen | 8.4-inch color LCD touch screen, supports Chinese operation |
| File storage | Detailed experimental data storage: 9,999 entries Instrument timing start/stop setting options: 99 types |
| Printer | Optional thermal printer or impact printer. |
| Moisture vaporization device | Can be used with VA-300, VA-200, VA-210, VA-230, VA-236S, VA-121, and VA-122 gasification units all feature stepwise temperature control functionality. |
| Bromine detection mode Burette |
Be equipped with Volume: 10 ml (2 ml, 5 ml, and 20 ml burettes available as optional accessories) Titration accuracy: 0.1% Reagent filling speed: 0.7 ml/1 sec |
| External Access I/O | Electronic balance: Automatic weight input 4 USB ports, 1 LAN port Import or export experimental data, backup/restore settings |
Keywords:
Related News